Attrezzatura |
Nome |
Inventario n. |
Note/Info |
VME 8010
|
Crate CAEN
|
x |
CAEN |
CAEN VME 8010 Crate – Info
|
Features
- Low cost compact solution
- 19″ x 7U (6+1) enclosure
- 21 slot for 6U x 160mm VME modules
- 470W Power Supply
- VME64 J1/J2 monolithic backplane
- Short circuit protection
- Over / Undervoltage protection
- Over temperature protection
- 1U space for Fan Unit
- Powered by 100÷230 VAC, 50 ÷ 60 Hz
- CBLT cycles supported
|
- Mechanics
-
7U bin for 6U x 160 mm VME cards, 21 slots, 1U space for fan tray
- Mains input
-
Auto range: 85 ÷264 Vac, 47÷63 Hz, inrush current: <40 A @ 264 Vac power. fact.: 0.99 Typical
- Fuse
-
F10 A, fast type
- Maximum Total Output Power
-
470 W @ 110 / 264 Vac
- Output power
-
60 A @ +5 V, 6 A @ -12 V, 8.9 A @ +12 V
- Isolation
-
CE acc. to EN 61010
- Regulation
-
< 25mV for 0-100% load change
- Noise and ripple
-
+5V < 50mV +12V < 90mV -12V < 90mV (measured at 90% of full load)
- RFI-rejection
-
CE EN 50081-1, FCC (emission), EN 50082-1 or 2 (immunity)
- Over Current Protection
-
Trip off at 105-125% of the nominal values
- Overvoltage protection
-
Trip off at 120-130% of the nominal values
- DC Off (trip off)
-
within 5 ms if +5%, -2.5% deviation from adjusted nominal values, after overload, overheat, over voltage, under voltage (bad status) and fan fail trip off voltages and currents adjustable, processor controlled
- Internal temperature limits
-
Cut off: 110 °C heat sink, 70 °C ambient, autom. maximum fan speed if air above VME modules >45°C
- Operation
-
0÷50°C without derating
- Temperature coefficient
-
< 0.2% / 10K
- Stability
-
10mV or 0.1% within 24 hours 50mV or 1.0% within 6 months
- Over Temperature Protection
-
Trip off all Output Voltages and PS internal fan
- Efficiency
-
75% typical at 230Vac & 100% rated power
- Cooling Airflow
-
408 m³/h (at maximum fan speed)
|
|