{"id":8564,"date":"2021-09-07T10:49:04","date_gmt":"2021-09-07T08:49:04","guid":{"rendered":"https:\/\/www.pi.infn.it\/?page_id=8564"},"modified":"2021-09-07T10:56:27","modified_gmt":"2021-09-07T08:56:27","slug":"at-db-0068","status":"publish","type":"page","link":"https:\/\/www.pi.infn.it\/?page_id=8564","title":{"rendered":"AT &#8211; db &#8211; 0068"},"content":{"rendered":"\n<table style=\"height: 48px;width: 101.314%;border-color: #e0dcdc\" border=\"5px\">\n<tbody>\n<tr>\n<td style=\"width: 25%;text-align: center\"><span style=\"color: #ff6600\"><em>Attrezzatura<\/em><\/span><\/td>\n<td style=\"width: 25%;text-align: center\"><span style=\"color: #ff6600\"><em>Nome<\/em><\/span><\/td>\n<td style=\"width: 25%;text-align: center\"><span style=\"color: #ff6600\"><em>Inventario n.<\/em><\/span><\/td>\n<td style=\"width: 25%;text-align: center\"><span style=\"color: #ff6600\"><em>Note\/Info<\/em><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%;text-align: center\"><em>Source Meter<\/em><\/td>\n<td style=\"width: 25%;text-align: center\"><em>Keithley 2410<\/em><\/td>\n<td style=\"width: 25%;text-align: center\"><em><strong>7361<\/strong><\/em><\/td>\n<td style=\"width: 25%;text-align: center\"><a href=\"https:\/\/www.tek.com\"><em>Keithley<\/em><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Keithley 2410 Source Meter- <a href=\"https:\/\/www.tek.com\/keithley-source-measure-units\/keithley-smu-2400-series-sourcemeter\">Info<\/a><br \/><\/em><\/p>\n<p><em>DataSheet &#8211; <a href=\"https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/09\/1KW-2798-3_2400_SourceMeter_SMU_Datasheet_041121.pdf\">Download<\/a><\/em><\/p>\n<table style=\"height: 48px;width: 101.314%;border-color: #e0dcdc\" border=\"5px\">\n<tbody>\n<tr>\n<td style=\"width: 100%\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-8569 size-large\" src=\"https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/09\/2400-Graphical-Series-SMU-1024x566.jpg\" alt=\"\" width=\"1024\" height=\"566\" srcset=\"https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/09\/2400-Graphical-Series-SMU-1024x566.jpg 1024w, https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/09\/2400-Graphical-Series-SMU-300x166.jpg 300w, https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/09\/2400-Graphical-Series-SMU-768x424.jpg 768w, https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/09\/2400-Graphical-Series-SMU.jpg 1280w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 100%\">\n<p>Keithley\u2019s Series 2400 Source Measure Unit (SMU) Instruments are designed specifically for test applications that demand tightly coupled sourcing and measurement. All SourceMeter models provide precision voltage and current sourcing as well as measurement capabilities. Each SourceMeter SMU instrument is both a highly stable DC power source and a true instrument-grade 6\u00bd-digit multimeter. The power source characteristics include low noise, precision, and readback. The multimeter capabilities include high repeatability and low noise. The result is a compact, single-channel, DC parametric tester. In operation, these instruments can act as a voltage source, a current source, a voltage meter, a current meter, and an ohmmeter. Manufacturers of components and modules for the communications, semiconductor, computer, automotive, and medical industries will find the SourceMeter SMU instruments invaluable for a wide range of characterization and production test applications.<\/p>\n<p>Key Features<\/p>\n<ul>\n<li>Five instruments in one (IV Source, IVR Measure)<\/li>\n<li>Five models: 20\u2013100 W DC, 1000 W pulsed, 1100 V to 1 \u00b5V<\/li>\n<li>Source and sink (4-quadrant) operation<\/li>\n<li>0.012% basic measure accuracy with 6\u00bd-digit resolution<\/li>\n<li>2-, 4-, and 6-wire remote V-source and measure sensing<\/li>\n<li>1700 readings\/second at 4\u00bd digits via GPIB<\/li>\n<li>Pass\/Fail comparator for fast sorting\/binning<\/li>\n<li>Programmable DIO port for automation\/handler\/prober control (except 2401)<\/li>\n<li>Standard SCPI GPIB, RS-232 and Keithley Trigger Link interfaces<\/li>\n<li>Download KickStart today and try it out for 60 days<\/li>\n<\/ul>\n<p>Advantages of a Tightly Integrated Instrument<\/p>\n<p>By linking source and measurement circuitry in a single unit, these instruments offer a variety of advantages over systems configured with separate source and measurement instruments. For example, they minimize the time required for test station development, setup, and maintenance, while lowering the overall cost of system ownership. They simplify the test process itself by eliminating many of the complex synchronization and connection issues associated with using multiple instruments. And, their compact half-rack size conserves precious \u201creal estate\u201d in the test rack or bench.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Attrezzatura Nome Inventario n. Note\/Info Source Meter Keithley 2410 7361 Keithley Keithley 2410 Source Meter- Info DataSheet &#8211; Download Keithley\u2019s Series 2400 Source Measure Unit (SMU) Instruments are designed specifically for test applications that demand tightly coupled sourcing and measurement. All SourceMeter models provide precision voltage and current sourcing as well as measurement capabilities. Each [&hellip;]<\/p>\n","protected":false},"author":30,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_links_to":"","_links_to_target":""},"publishpress_future_action":{"enabled":false,"date":"2026-05-13 20:28:11","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"language"},"_links":{"self":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages\/8564"}],"collection":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/users\/30"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8564"}],"version-history":[{"count":4,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages\/8564\/revisions"}],"predecessor-version":[{"id":8573,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages\/8564\/revisions\/8573"}],"wp:attachment":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8564"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}