{"id":8014,"date":"2021-07-30T14:16:20","date_gmt":"2021-07-30T12:16:20","guid":{"rendered":"https:\/\/www.pi.infn.it\/?page_id=8014"},"modified":"2021-07-30T14:23:43","modified_gmt":"2021-07-30T12:23:43","slug":"at-db-0030","status":"publish","type":"page","link":"https:\/\/www.pi.infn.it\/?page_id=8014","title":{"rendered":"AT &#8211; db &#8211; 0030"},"content":{"rendered":"\n<table style=\"height: 48px;width: 101.314%;border-color: #e0dcdc\" border=\"5px\">\n<tbody>\n<tr>\n<td style=\"width: 25%;text-align: center\"><span style=\"color: #ff6600\"><em>Attrezzatura<\/em><\/span><\/td>\n<td style=\"width: 25%;text-align: center\"><span style=\"color: #ff6600\"><em>Nome<\/em><\/span><\/td>\n<td style=\"width: 25%;text-align: center\"><span style=\"color: #ff6600\"><em>Inventario n.<\/em><\/span><\/td>\n<td style=\"width: 25%;text-align: center\"><span style=\"color: #ff6600\"><em>Note\/Info<\/em><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%;text-align: center\"><em>Keithley 2400 Source Meter<\/em><\/td>\n<td style=\"width: 25%;text-align: center\"><em>2400<\/em><\/td>\n<td style=\"width: 25%;text-align: center\"><em><strong>6726<\/strong><\/em><\/td>\n<td style=\"width: 25%;text-align: center\"><a href=\"https:\/\/www.tek.com\/datasheet\/series-2400-sourcemeter-instruments\"><em>DataSheet<\/em><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h5>Keithley 2400 Source Measure Unit<\/h5>\n<p><em>Manuale: <a href=\"https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/07\/1KW-2798-3_2400_SourceMeter.pdf\">1KW-2798-3_2400_SourceMeter<\/a><\/em><\/p>\n<table style=\"height: 48px;width: 101.314%;border-color: #e0dcdc\" border=\"5px\">\n<tbody>\n<tr>\n<td style=\"width: 100%\"><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-8021 size-full aligncenter\" src=\"https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/07\/Keithley-2400.jpg\" alt=\"\" width=\"500\" height=\"500\" srcset=\"https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/07\/Keithley-2400.jpg 500w, https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/07\/Keithley-2400-300x300.jpg 300w, https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/07\/Keithley-2400-150x150.jpg 150w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 100%\">\n<section id=\"pdpSection_FAndB\" class=\"product-overview collapsable full pdpProductContent open\" role=\"region\" aria-label=\"Panoramica del prodotto\" data-dojo-type=\"Collapsable\" data-dojo-props=\"cookie:true\">\n<div class=\"heading collapsable-trigger\" data-dojo-attach-point=\"trigger\">\n<h2>Panoramica del prodotto<\/h2>\n<\/div>\n<div class=\"collapsable-content\">\n<div class=\"contents\">The 2400 from Keithley is a 200V, 1A, 20W SourceMeter\u00ae unit (SMU) instrument. It is designed specifically for test applications that demand tightly coupled sourcing and measurement. This SMU provides precision voltage and current sourcing as well as measurement capabilities. It includes both a highly stable DC power source and true instrument grade 6.5 digit multimeter. The power source characteristics include low noise, precision and readback. The multimeter capabilities include high repeatability and low noise. The result is a compact, single channel, DC parametric tester. In operation, it can act as voltage source, current source, voltage meter, current meter and ohmmeter. Manufacturers of components and modules for communications, semiconductor, computer, automotive and medical industries will find SMU units invaluable for wide range of characterization and production test applications.<\/div>\n<div id=\"fnb_features\" class=\"featuresList\">\n<ul class=\"firstList\">\n<li>Power of five instruments in one (IV source, IVR measure), source and sink (4-quadrant) operation<\/li>\n<li>0.012% basic measure accuracy with 6\u00bd-digit resolution<\/li>\n<li>2-, 4-, and 6-wire remote V-source and measure sensing<\/li>\n<li>1700 readings\/second at 4.5 digits via GPIB<\/li>\n<li>Source and sink (four-quadrant) operation<\/li>\n<li>Pass\/fail comparator for fast sorting\/binning<\/li>\n<li>Programmable DIO port for automation\/handler\/prober control<\/li>\n<li>Standard SCPI GPIB, RS-232 and Keithley Trigger Link interfaces<\/li>\n<li>Perform I-V characterization using Keithley&#8217;s KickStart software<\/li>\n<li>89mm (H) x 213mm (W) x 370mm (D) dimension, 3.21kg weight<\/li>\n<\/ul>\n<\/div>\n<div class=\"productContentContainer\">\n<h3>Sommario<\/h3>\n<p class=\"pdpContentLists\">2400 SourceMeter\u00ae unit, Model 8605 test leads, Documentation (downloadable), KickStart start-up software (downloadable), LabVIEW and IVI drivers (downloadable).<\/p>\n<\/div>\n<\/div>\n<\/section>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Attrezzatura Nome Inventario n. Note\/Info Keithley 2400 Source Meter 2400 6726 DataSheet Keithley 2400 Source Measure Unit Manuale: 1KW-2798-3_2400_SourceMeter Panoramica del prodotto The 2400 from Keithley is a 200V, 1A, 20W SourceMeter\u00ae unit (SMU) instrument. It is designed specifically for test applications that demand tightly coupled sourcing and measurement. This SMU provides precision voltage and [&hellip;]<\/p>\n","protected":false},"author":30,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_links_to":"","_links_to_target":""},"publishpress_future_action":{"enabled":false,"date":"2026-05-15 16:56:54","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"language"},"_links":{"self":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages\/8014"}],"collection":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/users\/30"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8014"}],"version-history":[{"count":5,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages\/8014\/revisions"}],"predecessor-version":[{"id":8025,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages\/8014\/revisions\/8025"}],"wp:attachment":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8014"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}