{"id":7772,"date":"2021-07-29T15:16:16","date_gmt":"2021-07-29T13:16:16","guid":{"rendered":"https:\/\/www.pi.infn.it\/?page_id=7772"},"modified":"2021-07-30T15:23:57","modified_gmt":"2021-07-30T13:23:57","slug":"at-db-0017","status":"publish","type":"page","link":"https:\/\/www.pi.infn.it\/?page_id=7772","title":{"rendered":"AT &#8211; db &#8211; 0017"},"content":{"rendered":"\n<table style=\"height: 48px;width: 101.314%;border-color: #e0dcdc\" border=\"5px\">\n<tbody>\n<tr>\n<td style=\"width: 39.3361%;text-align: center\"><span style=\"color: #ff6600\"><em>Attrezzatura<\/em><\/span><\/td>\n<td style=\"width: 20.0646%;text-align: center\"><span style=\"color: #ff6600\"><em>Nome<\/em><\/span><\/td>\n<td style=\"width: 15.5993%;text-align: center\"><span style=\"color: #ff6600\"><em>Inventario n.<\/em><\/span><\/td>\n<td style=\"width: 25%;text-align: center\"><span style=\"color: #ff6600\"><em>Note\/Info<\/em><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.3361%;text-align: center\"><em>Keithley 237 Power Supply &#8211; High Voltage<br \/><\/em><\/td>\n<td style=\"width: 20.0646%;text-align: center\"><em>Keithley 237<\/em><\/td>\n<td style=\"width: 15.5993%\">\u00a0<\/td>\n<td style=\"width: 25%;text-align: center\"><a href=\"https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/07\/237.pdf\"><em>Manuale<\/em><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h5>Keithley Model <em>237<\/em> Source-Measure Unit is a Fully Programmable Instrument<\/h5>\n<h5><span class=\"fontstyle0\">High Voltage Source-Measure Unit<\/span> <\/h5>\n<table style=\"height: 48px;width: 101.314%;border-color: #e0dcdc\" border=\"5px\">\n<tbody>\n<tr>\n<td style=\"width: 100%\"><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-7776 size-full aligncenter\" src=\"https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/07\/Keythley-237.jpg\" alt=\"\" width=\"340\" height=\"148\" srcset=\"https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/07\/Keythley-237.jpg 340w, https:\/\/www.pi.infn.it\/wp-content\/uploads\/2021\/07\/Keythley-237-300x131.jpg 300w\" sizes=\"(max-width: 340px) 100vw, 340px\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 100%\"><span class=\"fontstyle0\">The Model 237 Source-Measure Unit is a fully programmable instrument, capable of sourc ing and<br \/>measuring voltage or current simultaneously. This system is really four instruments in one: voltage<br \/>source, current source, voltage measure, and current measure.<br \/><\/span><span class=\"fontstyle2\">Applications<br \/><\/span><span class=\"fontstyle0\">This SMU instrument addresses a wide variety of applications, including the characteri zation of semiconductor devices and the measurement of leakage currents or insulation resistance. It can be used<br \/>standalone on a bench, in a test rack with PC control, or integrated with our Model 4200-SCS for<br \/>high voltage semicconductor characterization.<br \/><\/span><span class=\"fontstyle2\">Wide Dynamic Range<br \/><\/span><span class=\"fontstyle0\">The Model 237 will source voltage from 100\u00b5V to 1100V, and current from 100fA to 100mA. It can<br \/>also measure voltage from 10\u00b5V to 110V and current from 10fA to 100mA. In the higher voltage<br \/>range, current source and measure is 10mA maximum.<br \/><\/span><span class=\"fontstyle2\">Selectable Sweeps of Voltage and Current<br \/><\/span><span class=\"fontstyle0\">The Model 237 can be programmed to perform source-measurements as a function of a stepped<br \/>voltage or current. Voltage and current can be swept linearly, logarithmically, or pulsed. The START,<br \/>STOP, STEP method of setting sweep parameters allows operators to become proficient at using the<br \/>instru ment very quickly. Sweep para me ters may be appended (APPEND key) to obtain more complex<br \/>test sequences.<br \/>Creating custom sweeps of voltage or current is<br \/>facilitated by the use of three waveform opera tions: CREATE, APPEND, and MODIFY. These<br \/>allow the user to select waveform parameters,<br \/>com bine multiple waveforms, and select and<br \/>change any points in a waveform previously crea &#8211;<br \/>t ed or appended.<br \/><\/span><span class=\"fontstyle2\">Fully-Guarded Four-Terminal<br \/>Measurements<br \/><\/span><span class=\"fontstyle0\">The Model 237 outputs and inputs are fully<br \/>guard ed, and the units are configured to allow<br \/>four-terminal measurements. Two-terminal measurements are also available for more standard test<br \/>procedures. These outputs can be floated up to<br \/>\u00b1200V from ground<\/span> <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Attrezzatura Nome Inventario n. Note\/Info Keithley 237 Power Supply &#8211; High Voltage Keithley 237 \u00a0 Manuale Keithley Model 237 Source-Measure Unit is a Fully Programmable Instrument High Voltage Source-Measure Unit The Model 237 Source-Measure Unit is a fully programmable instrument, capable of sourc ing andmeasuring voltage or current simultaneously. This system is really four instruments [&hellip;]<\/p>\n","protected":false},"author":30,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_links_to":"","_links_to_target":""},"publishpress_future_action":{"enabled":false,"date":"2026-05-15 06:15:00","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"language"},"_links":{"self":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages\/7772"}],"collection":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/users\/30"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7772"}],"version-history":[{"count":9,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages\/7772\/revisions"}],"predecessor-version":[{"id":8046,"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=\/wp\/v2\/pages\/7772\/revisions\/8046"}],"wp:attachment":[{"href":"https:\/\/www.pi.infn.it\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7772"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}